Disconnect the appliance from the electric supply before refilling liquid, cleaning or performing maintenance on the machine. Not designed for outside use. Prior to use take care to determine that the unit is installed at the rated voltage. If moisture, water, or fog fluid gets inside the housing, immediately unplug the unit and wipe it with clean dry cloth.

Never leave the unit running unattended. Avoid coming within 60 cm of the output nozzle during operation. You now own a rugged and powerful state-of-the- art machine. Prior to use, we suggest that you carefully read all of the instructions. By following the suggestions found in this user manual, you can look forward to the reliable and satisfactory performance of your ANTARI Fog Machine for years to come.

Please follow these operation, safety and maintenance instructions to ensure a long and safe life for your fog machine. Risk of electric shock. Disconnect the appliance from the electric supply before refilling liquid, cleaning or performing maintenance on the machine.

For all models, use 3-prong grounded electrical outlet only. Prior to use take care to determine that the unit is installed at the rated voltage. This machine is not water-proof. If moisture, water, or fog fluid gets inside the housing, immediately unplug the unit and contact a service technician or your ANTARI dealer before using it again. No user serviceable parts inside. This device is for adult use only and must be installed out of the reach of children.

Never leave the unit running unattended. Fog machine output is very hot. Avoid coming within 60 cm of the output nozzle during operation. Locate the fog machine in a well-ventilated area. In order to guarantee adequate ventilation, allow a free air space of at least 20 cm around the sides and top of the unit. If the supply cord is damaged, it must be replaced by manufacturer or its service agent or similarly qualified personnel in order to avoid a hazard.

Keep flammable materials at least 50 cm away from the nozzle. Never add flammable liquids of any kind such as oil, gas, perfume to the fog liquid. Use only high-quality, water-based fog liquid that your dealer recommends. Always make sure there is sufficient liquid in the tank.

Operating this unit without liquid will cause damage to the pump as well as over-heating of the heater. Drain all fog liquid from the tank, pack the unit securely preferably in the original packing material , and return it to your ANTARI dealer for service. Never drink fog liquid. If it is ingested, call a doctor immediately. If fog liquid comes in contact with skin or eyes, rinse thoroughly with water.

Open the shipping carton and verify that all equipment necessary to operate the system has arrived intact. The shipping carton should contain the following items:. Remove all packing materials from shipping box. Check that all foam and plastic padding is removed, especially in the nozzle area. Any other types of fluid can damage the unit resulting in spitting and serious clogging problem. When filled, place cap back on liquid tank. Be careful not to exceed the maximum fluid level.

Firmly attach the remote control cable to the proper input on the back of the machine. Plug power cord into a grounded electrical outlet. The unit will take a couple of minutes to warm up the heater. During this time the machine cannot generate fog. When the remote control is attached the red lights on ZII handle and green light on the remote will flash and stay ON when the warm-up time is complete.

To emit fog press the button on the remote if it is connected and on the handle for ZII for the desired length of time. Important: Always monitor tank fluid level as you are fogging. Running a fog machine with no fluid can permanently damage the unit.

ZII: Your model includes a mounting bracket designed for overhead installation; it may be installed at floor level or suspended overhead.

Whatever installation method you choose, do not allow the unit to have more than a 25 degree angle of inclination. Note: A fluid level sensor is installed on the unit.

The machine will stop to fog if the fluid is lower than usable level. If you experience low output, pump noise or no output at all, unplug immediately. Check fluid level, the external fuse, remote control connection and power from the wall. If all of the above appears to be O. If fog does not come out after holding the remote button down for 30 seconds, check the hose attached to the tank to make sure there is fluid going through the hose.

If you are unable to determine the cause of the problem, do not simply continue pushing the remote button, as this may damage the unit. The red lamp indicates that the unit is receiving power. When the fog machine has reached operating temperature the green light on this remote control will light up, indicating that the operator may begin fog emission by pressing the red button. The green light flashes during fog machine warm-up and re-heating cycles approx. Its two knobs allow the operator to customize fog machine functions by adjusting output duration and interval.

When pressed, the green FOG button overrides all other control functions and activates maximum output. A remote operation is possible up to a distance of 50 meters. Keep the red button pressed for fogging. All fog machines develop condensation around the output nozzle. Because this may result in some moisture accumulation on the surface below the output nozzle, consider this condensation when installing your unit.

All fog machines may sputter small amounts of fog occasionally during operation and for a minute or so after being turned off.

All fog machines have a recycling period after long bursts when the machine will shut itself down for a short period in order to heat up again. During this time no fog can be produced. Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid container and the fog machine liquid tank immediately after filling.

Empty all fog liquid from the machine.