To avoid them being released outside and to minimize the waste of natural resources, we suggest you reasonably call back this device to ensure proper recovery and recycling of most materials within it. By using the three methods the oscilloscope provides context-sensitive, hyperlinks, and an index , you may master all operations on the device in quite a short time so as to greatly improve your efficiency in production and development.
This oscilloscope has a Help system with topics covering all of its features. You can use the Help system to display several kinds of information:. The Help system provides three methods for you to find the information you want: context-sensitive, hyperlinks, and an index.
Push the HELP front-panel button and the oscilloscope displays information about the last menu displayed on the screen. They are links to other topics. Push the Show Topic option button to display the topic corresponding to the highlighted link. Press the Back option button to return to the previous topic. Push the Page Up or Page Down option button until you find the index page which contains the topic you want to view.
Press the Show Topic option button to display the topic. NOTE: Press the Exit option button or any menu button to remove the Help text from the screen and return to displaying waveforms. To keep proper ventilation of the oscilloscope in operation, leave a space of more than 5cm away from the top and the two sides of the product. The default Probe option attenuation setting is 10X. Set the switch on the probe to 10X and connect the probe to Channel 1 on the oscilloscope.
When using the probe, keep your fingers behind the guard on the probe body to avoid electric shock. Do not touch metallic portions of the probe head while it is connected to a voltage source.
Connect the probe to the oscilloscope and connect the ground terminal to ground before you start any measurements. Every time you connect a probe to an input channel, you should use the probe check wizard to verify that this probe is operating correctly. There are two ways to do this:.
Upon the first connection of a probe and an input channel, you should manually perform this adjustment to match the probe to the input channel. Uncompensated or miscompensated probes may lead to errors or faults in measurement. To adjust the probe compensation, follow the steps below. Set the Probe option attenuation in the channel menu to 10X. If you use the probe hook-tip, ensure it is firmly inserted onto the probe. If necessary, use a nonmetallic screwdriver to adjust the variable capacity of your probe until the shape of the waveform turns to be the same as the above figure.
Repeat this step as necessary. See the figure below for the way of adjustment. Probes are of various attenuation factors which affect the vertical scale of the signal. The Probe Check function is used to verify if the Probe attenuation option matches the attenuation of the probe.
As an alternative method to Probe Check, you can push a vertical menu button such as the CH 1 MENU button and select the Probe option that matches the attenuation factor of your probe. Make sure that the Attenuation switch on the probe matches the Probe option in the oscilloscope.
Switch settings are 1X and 10X. When the Attenuation switch is set to 1X, the probe limits the bandwidth of the oscilloscope to 6MHz. To use the full bandwidth of the oscilloscope, be sure to set the switch to 10X.
The self calibration routine helps optimize the oscilloscope signal path for maximum measurement accuracy. For a more accurate calibration, please power on the oscilloscope and wait for 20 minutes until it has adequately warmed up. To compensate the signal path, disconnect any probes or cables from the front-panel input connectors. Chapter 4 Main Feature Description This chapter provides some general information that you need to learn before using an oscilloscope.
Tektronix proprietary sampling technology provides real-time sampling with a minimum of 10X over sampling on all channels, all the time to accurately capture your signals. Sampling performance is not reduced when using multiple channels. Quickly perform an FFT or add, subtract, or multiply waveforms. Sixteen automated measurements quickly and reliably calculate important signal characteristics such as frequency or rise time, while the built-in Limit Test function enables you to easily identify problems in your signal.
The Tektronix TDSC Series oscilloscopes are designed with the ease of use and familiar operation you have come to expect from Tektronix. The intuitive user interface with dedicated per-channel vertical controls, auto-setup, and auto-ranging makes these instruments easy to use, reducing learning time and increasing efficiency. See all the details other oscilloscopes might miss with Tektronix proprietary digital real-time sampling.
Help is provided in the same languages as the user interface. Check out your probe compensation before making measurements with just one button that starts a fast, easy procedure. The Tektronix TDSC oscilloscope can automatically monitor source signals and output Pass or Fail results by judging whether the input waveform is within predefined boundaries.
The Tektronix TDSC oscilloscope can automatically monitor source signals and output Pass or Fail results by judging whether the input waveform is within predefined boundaries. Specifications can be triggered on violation including stopping waveform acquisition, stopping Limit Test functions, saving the failed waveform data or screen image to a USB memory device, or any combination of the above.
This is an ideal solution for manufacturing or service applications where you need to make decisions quickly. The USB host port on the front panel enables you to save your instrument settings, screenshots, and waveform data in a flash.
The built-in datalogging feature means you can setup your oscilloscope to save user-specified triggered waveforms to a USB memory device for up to 8 hours. Simply pull screen images and waveform data into the stand-alone desktop application or directly into Microsoft Word and Excel. Alternatively, if you prefer not to use your PC, you can simply print your image directly to any PictBridge-compatible printer.
Signal Express supports the range of Tektronix bench instruments enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time correlate data from multiple instruments, and easily capture and analyze your results, all from your PC.